User contributions
From Nuclear Physics Group Documentation Pages
Jump to navigationJump to search- 20:03, 13 August 2020 diff hist +320 N TE Measurements Created page with "When taking a TE, ensure the following is true for a Good TE: * The TE value should not change by more than 10%, preferably much less, within 10 minutes, within 10 minutes be..." current
- 20:02, 13 August 2020 diff hist +37 Shift Workers Documentation
- 23:07, 12 August 2020 diff hist +1 UNH DNP →Target Cool Downs current
- 23:07, 12 August 2020 diff hist -18 UNH DNP →Target Cool Downs
- 23:05, 12 August 2020 diff hist 0 UNH DNP →Target Cool Downs
- 23:04, 12 August 2020 diff hist +234 UNH DNP →Target Cool Downs
- 20:39, 12 August 2020 diff hist +265 N Magnet refills Created page with "The procedure for filling the magnet with liquid helium is outlined in the 'Transferring Liquid Helium' section of the Cool-Down Procedures document found at https://docs.goog..."
- 20:39, 12 August 2020 diff hist -306 Monitor LHe level in the Magnet and call for fillings Blanked the page current
- 20:39, 12 August 2020 diff hist +306 N Monitor LHe level in the Magnet and call for fillings Created page with " =Filling the LHe Level in the Magnet= The procedure for filling the magnet with liquid helium is outlined in the 'Transferring Liquid Helium' section of the Cool-Down Proce..."
- 20:37, 12 August 2020 diff hist +23 Ramp up and down the magnet current
- 20:36, 12 August 2020 diff hist +246 N Monitor/Operating needle valves Created page with "This can currently be found under 'Cooling the LHe Evaporation Fridge' that starts on Page 9 of the Cool-Down Procedures document found at https://docs.google.com/document/d/1..."
- 20:34, 12 August 2020 diff hist +162 N Ramp up and down the magnet Created page with "This procedure is outlined on Page 10 of the Cool-Down Procedures document at https://docs.google.com/document/d/1ecbCTTtgoKBhofpUS1OsZVxOxAfA9XxAiUHVvF13A3o/edit"
- 20:33, 12 August 2020 diff hist +1,204 N Heat Straps monitor / External heater of the separator line Created page with "=Heat Straps= Often, heat straps are put on the exterior of the shells below the large ISO-200 Tee and above the blue magnet dewar. This helps to keep the electronics from fr..." current
- 20:28, 12 August 2020 diff hist +37 VNA/VME swaps and calibrations →VNA current
- 20:01, 12 August 2020 diff hist +50 VNA/VME swaps and calibrations →VNA
- 20:00, 12 August 2020 diff hist +6 N VNA/VME swaps and calibrations Created page with " =VNA="
- 15:00, 25 June 2020 diff hist +9 Running EIC Simulations →BeAGLE current
- 14:59, 25 June 2020 diff hist -1 Running EIC Simulations →BeAGLE
- 14:59, 25 June 2020 diff hist -1 Running EIC Simulations →BeAGLE
- 14:58, 25 June 2020 diff hist +4 Running EIC Simulations →BeAGLE
- 14:53, 25 June 2020 diff hist 0 Running EIC Simulations →ESCalate
- 14:53, 25 June 2020 diff hist +1 Running EIC Simulations →ESCalate
- 14:52, 25 June 2020 diff hist +202 Running EIC Simulations →ESCalate
- 14:37, 25 June 2020 diff hist -1 Running EIC Simulations →ESCalate
- 14:36, 25 June 2020 diff hist 0 Running EIC Simulations →ESCalate
- 14:36, 25 June 2020 diff hist +627 Running EIC Simulations →ESCalate
- 14:23, 25 June 2020 diff hist +631 Running EIC Simulations →ESCalate
- 14:16, 25 June 2020 diff hist +2,126 Running EIC Simulations →BeAGLE
- 14:03, 25 June 2020 diff hist +66 Running EIC Simulations →BeAGLE
- 14:02, 25 June 2020 diff hist +2 Running EIC Simulations →BeAGLE
- 13:52, 25 June 2020 diff hist -10 Running EIC Simulations →BeAGLE
- 13:51, 25 June 2020 diff hist -2 Running EIC Simulations →BeAGLE
- 13:51, 25 June 2020 diff hist +18 Running EIC Simulations →BeAGLE
- 13:51, 25 June 2020 diff hist +1,783 N Running EIC Simulations Created page with "==BeAGLE== BeAGLE is currently the best electron-deuteron scattering generator for the EIC. In order to run BeAGLE, currently that can be done on the JLab ifarm computers. To..."
- 13:49, 25 June 2020 diff hist +29 UNH DNP →Lab How-To/Info
- 17:57, 12 June 2020 diff hist +53 Monitor and operate the microwaves / know how to find correct frequency →Proton Enhancement current
- 17:53, 12 June 2020 diff hist -1 Monitor and operate the microwaves / know how to find correct frequency →Proton Enhancement
- 17:53, 12 June 2020 diff hist +1 Monitor and operate the microwaves / know how to find correct frequency →Proton Enhancement
- 17:52, 12 June 2020 diff hist +23 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 17:50, 12 June 2020 diff hist +589 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 17:46, 12 June 2020 diff hist +140 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 17:44, 12 June 2020 diff hist +1,184 Monitor and operate the microwaves / know how to find correct frequency →Proton Frequency
- 17:29, 12 June 2020 diff hist 0 File:Proton mmwaves.png Elong uploaded a new version of "File:Proton mmwaves.png" current
- 17:27, 12 June 2020 diff hist 0 File:Proton mmwaves.png Elong uploaded a new version of "File:Proton mmwaves.png"
- 17:23, 12 June 2020 diff hist +7 Monitor and operate the microwaves / know how to find correct frequency →Proton Frequency
- 17:22, 12 June 2020 diff hist 0 N File:Proton mmwaves.png
- 17:21, 12 June 2020 diff hist +323 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 21:26, 11 June 2020 diff hist +8 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 21:24, 11 June 2020 diff hist +252 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency
- 21:19, 11 June 2020 diff hist -1 Monitor and operate the microwaves / know how to find correct frequency →Finding the correct frequency