General Information
Lentil performs backups. Its backup script needs further investigation to determine exactly how it works.
Network Configuration
Hostnames: lentil.unh.edu, lentil.farm.physics.unh.edu
Currently connected to the unh and farm networks via the switch and VLAN.
ifconfig
eth0 Link encap:Ethernet HWaddr 00:23:54:BC:70:F1 inet addr:10.0.0.250 Bcast:10.0.0.255 Mask:255.255.255.0 inet6 addr: fe80::223:54ff:febc:70f1/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:30404 errors:0 dropped:0 overruns:0 frame:0 TX packets:1778 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3723593 (3.5 MiB) TX bytes:227139 (221.8 KiB) Interrupt:66 Base address:0x6000 eth0.2 Link encap:Ethernet HWaddr 00:23:54:BC:70:F1 inet addr:132.177.88.254 Bcast:132.177.91.255 Mask:255.255.252.0 inet6 addr: fe80::223:54ff:febc:70f1/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:28826 errors:0 dropped:0 overruns:0 frame:0 TX packets:1032 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:3068357 (2.9 MiB) TX bytes:114723 (112.0 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:99 errors:0 dropped:0 overruns:0 frame:0 TX packets:99 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:9335 (9.1 KiB) TX bytes:9335 (9.1 KiB) virbr0 Link encap:Ethernet HWaddr 00:00:00:00:00:00 inet addr:192.168.122.1 Bcast:192.168.122.255 Mask:255.255.255.0 inet6 addr: fe80::200:ff:fe00:0/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:54 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 b) TX bytes:10754 (10.5 KiB)
Access Configuration
/etc/security/access.conf Any valid user can log into lentil from any machine on the Internet.
Backup Configuration
Location of Backups
/mnt/npg-daily/34/
All backup related scripts are:
/etc/auto.npg-daily /usr/local/bin/rsync_backup.pl /etc/cron.daily/0rsync_backup /usr/sbin/vgcfgbackup /etc/rsync-backup.conf
/etc/rsync-backup.conf
# Backups are 'pull' only. Too bad there isn't a better way to enforce this. read only = yes # Oh for the ability to retain CAP_DAC_READ_SEARCH, and no other. #uid = root # XXX There seems to be an obscure bug with pam_ldap and rsync whereby # getpwnam(3) segfaults when (and only when) archiving /etc. Using a numeric # uid avoids this bug. Only verified on Fedora Core 2. uid = 0 # There's not much point in putting the superuser in a chroot jail # use chroot = yes # This isn't really an effective "lock" per se, since the value is per-module, # but there really ought never be more than one, and it would at least # ensure serialized backups. max connections = 1 [usr_local] path = /usr/local comment = unpackaged software [opt] path = /opt comment = unpackaged software [etc] path = /etc comment = conf files [var] path = /var comment = user and system storage
SNMP Configuration
/etc/snmp/snmpd.conf Copied from Pepper.
Smartd Configuration
The configuration file is at /etc/smartd.conf. The smartd.conf does a silent check, which only emails reports if the SMART health status comes back as failed. This smartd.conf will look different from alot of the other computers because it doesn't have a RAID card installed, so each disk is mounted seperately for backups. [[[SMARTD]] Smartd setup and configuration]
rc.local Configuration
This script is modified to run commands when the system is done powering on.
/etc/rc.local
#!/bin/sh # # This script will be executed *after* all the other init scripts. # You can put your own initialization stuff in here if you don't # want to do the full Sys V style init stuff. touch /var/lock/subsys/local #This will send the boot.log to npg-admins everytime the pc is started. mail -s "$HOSTNAME Started, Here is the boot.log" npg-admins@physics.unh.edu < /var/log/boot.log
Hardware Information
Motherboard: Asus P5QL-CM Specifications: Specifications User Manual: V2.pdf Users Manual Memory: 2 GB DDR2 Wake On Lan Command: sudo ether-wake 00:1e:4f:9b:13:90
Fixes
- Kernel Crash Fix (2/24/2009)