Difference between revisions of "2018-04-10 Cool Down Analysis"
From Nuclear Physics Group Documentation Pages
Jump to navigationJump to search| Line 26: | Line 26: | ||
|} | |} | ||
| − | |||
| + | '''Magnet temperatures and Helium lost estimations.''' | ||
| + | [[Image:04-12-2018 magnetT.jpg|frame|thumbnail||1000px]] | ||
| + | '''Fridge Temperatures during the day.''' | ||
[[Image:04-12 fridgeT.png|1000px]] | [[Image:04-12 fridgeT.png|1000px]] | ||
| + | '''Fridge Temperatures during the cooldownffrom Room Temperature''' | ||
[[Image:04-12 fridge coolingT.png|900px]] | [[Image:04-12 fridge coolingT.png|900px]] | ||
| + | '''Fridge Temperatures at 1.2 K''' | ||
[[Image:04-12 fridge 1KT.png|1000px]] | [[Image:04-12 fridge 1KT.png|1000px]] | ||
| + | '''Fridge Temperatures at 2 K and without the roots''' | ||
[[Image:04-12 fridge TET.jpg|1000px]] | [[Image:04-12 fridge TET.jpg|1000px]] | ||
| + | |||
| + | '''Target Temperatures during the days''' | ||
[[Image:04-12 targetT.jpg|1000px]] | [[Image:04-12 targetT.jpg|1000px]] | ||
| + | |||
[[Image:04-12-2018 targetgoodT.jpg|1000px]] | [[Image:04-12-2018 targetgoodT.jpg|1000px]] | ||
[[Image:04-12-2018 targetflowT.jpg|1000px]] | [[Image:04-12-2018 targetflowT.jpg|1000px]] | ||
Revision as of 15:44, 23 April 2018
04/12/2018 Fridge Cooldown
The fridge was cool-down starting from room temperature on April 12. The steps that day can be summarized as:
| Time | Process | Comment | ||||
|---|---|---|---|---|---|---|
| 10:30 am - 2 pm | Cooling down the separator | Both needle valves closed and Separator pump flow constant at ~ 5 slm | ||||
| 2 pm - 5 pm | Nose cooldown to 1.2 K. | The needle valves were opened (both). The roots were on When the temperature in the nose decrease bellow 4 K, the bypass valve was closed and the heat exchanger was opened slightly. | ||||
| 5 pm - 10 pm | Thermal equilibrium conditions ~1.9 K. | The bypass valve was closed and the heat exchanger was opened slightly. The roots were off and a secondary small roughing pump was pumping the cryostat space. | 10 pm - 12 am | System off. | The needles valve were close and the separator pump was off. |
Magnet temperatures and Helium lost estimations.
Fridge Temperatures during the day.
Fridge Temperatures during the cooldownffrom Room Temperature
Fridge Temperatures at 1.2 K
Fridge Temperatures at 2 K and without the roots
Target Temperatures during the days