Difference between revisions of "Link to Page"

From Nuclear Physics Group Documentation Pages
Jump to navigationJump to search
 
Line 1: Line 1:
s
+
== Related Papers ==
 +
===Silicon Vertex Detectors===
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-4D0Y6DP-1&_user=1967573&_coverDate=11%2F11%2F2004&_alid=636311647&_rdoc=11&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=90&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=38fb3a7edace710fd475f3a01a9f5fd8 A new Monte Carlo code for full simulation of silicon strip detectors] [http://nuclear.unh.edu/secure/Silicon_Strip_Detector_Simulation_NIM533_322.pdf Local Copy ]
 +
**Detailed description of simulation design for ionization and signal readout in SSD
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-4FKY7FT-1&_user=1967573&_coverDate=04%2F01%2F2005&_alid=627076008&_rdoc=23&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=79&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=a8a9aac50928fdb047ba2133e9c04b00 Silicon tracking detectors - historical overview]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-41F5X25-9&_user=1967573&_coverDate=10%2F11%2F2000&_alid=627077088&_rdoc=26&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=93&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=513a697b1624ddaf8b5619e004dd3123 Overview: silicon vertex detectors and trackers]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-46MC9SG-7&_user=1967573&_coverDate=01%2F01%2F1995&_alid=627078546&_rdoc=7&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=171&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=a86eaec2a3c0ddf31483c56258ed48b8 Characterization and quality control of silicon microstrip detectors with an infrared diode laser system]
 +
**Useful for studying angle of incidence of laser in tests
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-470FCC6-TH&_user=1967573&_coverDate=01%2F01%2F1993&_alid=627080328&_rdoc=38&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=77&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=e37879eab740fc952d8a182cb99f97f1  The OPAL milicon microvertex detector] [http://nuclear.unh.edu/secure/OPAL_SVT_NIM_A324_34.pdf | Local Copy ]
 +
**Heavy in readout electronics and algorithms
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-470FC4B-PP&_user=1967573&_coverDate=07%2F15%2F1988&_alid=627081491&_rdoc=22&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=87&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=4e664556fa71769632bd598dbbfa2215 Infrared light charge injector as a tool for the study of silicon detectors]
 +
 
 +
===Micromegas Detectors===
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-3VSPXSV-Y&_user=1967573&_coverDate=06%2F21%2F1996&_alid=636332497&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=e234b18f985161d8372a825460c25e1e Micromegas: a high-granularity position-sensitive gaseous detector for high particle-flux environments]
 +
**Initial paper on Micromegas
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-3VHW9D0-8&_user=1967573&_coverDate=12%2F21%2F1998&_alid=636333833&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=a223645319adabdec0a3b9c7efb5a569 Development and prospects of the new gaseous detector "Miromegas"]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-3VPCFGM-5&_user=1967573&_coverDate=02%2F21%2F1999&_alid=636334586&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=0e50030780c1773c770913adb1e8deb9 Development of a fast gaseous detector: 'Micromegas']
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-430WX8M-W&_user=1967573&_coverDate=04%2F01%2F2001&_alid=636335429&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=bf6be193322b130bbcfaaf14bccb4166 Spatial resolution and rate capabilities of Micromegas detector]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-45HFC9M-1B&_user=1967573&_coverDate=02%2F01%2F2002&_alid=636336699&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=505228ff2b41c67e5bff1d6858d013d5 Tracking with 40x40 cm square Micromegas detectors in tyhe high energy, high luminosity COMPASS experiment]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-45HFC9M-1C&_user=1967573&_coverDate=02%2F01%2F2002&_alid=636343096&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=6db3290e2d6b0b3e9d4a8a355a11cded Electron drift velocity measurements at high electric fields]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-4J3NWY9-4&_user=1967573&_coverDate=05%2F10%2F2006&_alid=636343872&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=60b0b0c4e0fcb88acd67f5a22e15737a Micromegas in a bulk]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-4MCW7M1-N&_user=1967573&_coverDate=04%2F01%2F2007&_alid=636344447&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=154be31a8f397f0b63558168f0356f68 Performance of the Micromegas detector in the CAST experiment]
 +
 
 +
*[http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TJM-4MYVG40-3&_user=1967573&_coverDate=06%2F11%2F2007&_alid=636345106&_rdoc=1&_fmt=full&_orig=search&_cdi=5314&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000053403&_version=1&_urlVersion=0&_userid=1967573&md5=b743d729ebabdd390f3d43caf1dd33b6 On the geometrical design of integrated Micromegas detectors]
 +
 
 +
==Relevant Parameters==
 +
{| border="1" cellspacing="0" cellpadding="1"
 +
|- style="font-color:blue;font-weight:bold"
 +
|  || CN 2006-014 || CN 2006-016
 +
| colspan="2" |
 +
NIM 533 
 +
| colspan="3" |
 +
NIM 541 
 +
| NIM 453 || NIM 352 || NIM 324 || NIM 270 ||  || NIM 560 ||  ||  ||  || NIM 501 || NIM 485 ||  ||  ||  ||  || NIM 581 ||  || NIM in press ||  ||  ||  ||  ||
 +
|-
 +
| Thickness (_m) || 300-320 || 300 || 400 || 325 || 400 || 280 ||  || 300 || 300 || 300 ||  || 200 ||  ||  ||  ||  || 300 || 320±15/320±15 || 290±15/295±15 ||  ||  ||  || 300 ||  || 300 ||  || 300 ||  || 300 ||
 +
|-
 +
| Implant Strip Pitch (_m) || 75 || 75 || 228 || 25 || 100/200 || 20 || "25 || 29 || 33" || 25 || 25 || 25 || 10 to 50 || 500 || 75 || 50 || 73 || 65 || 88 || 60 || 80 || 120 || 240 ||  || 120 ||  || 75 || 50 || 73 || 65 || 76 || 25.5
 +
|-
 +
| Readout Strip Pitch (_m) || 150 || 150 ||  ||  ||  ||  ||  || 50 || 50 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  || 150 || 50 || 146 || 65 || 152 || 51
 +
|-
 +
| Strip Width (_m) || 9 ||  || 60 || 12 ||  ||  ||  ||  ||  ||  ||  ||  || 50 || 10 || 55 || 12 ||  || 10 || 15 || 25 || 35 || up to 86 || 14 ||  || 50 || 10 || 55 || 12 || 24 || 10
 +
|-
 +
| Implant Depth (_m) || 1.2 ||  || 5 || 5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  || 1 || 2 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
| # Readout Strips || 256 || 256 ||  ||  ||  ||  || 512 ||  ||  || 629 ||  || 56 || 1024 || 512 || 1024 || 512 ||  ||  ||  ||  ||  ||  || 512 ||  || 1024 || 512 || 1024 || 512 || 1024 || 512
 +
|-
 +
| Strip Angle (degrees) || ±1.5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
| Cut Size (mm x mm) || 42.0 x 111.62 || 42.0 x 111.62 ||  ||  || 24 x 30 || 24 x 36 ||  ||  ||  || 33 x 60 ||  || 30 x 30 || 79.2 x 28.4 ||  ||  ||  || 59 x 34 ||  ||  ||  ||  ||  || 64.2 x 64.2 ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
|  Active Area (mm x mm) || 40.0 x 109.62 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
| Depletion Voltage (V) || 40<V<200 ||  || 100 || 100 ||  ||  ||  ||  ||  || 35 ||  || ~40 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  || 40<V<100 ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
|  Readout Chip || SVX4 ||  ||  ||  ||  ||  ||  ||  || Tektronix DSA602A || FoxFET ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
|  Spatial Resolution (_m) ||  || ~40 _ ~20 ||  ||  ||  || 4.5 to 7 ||  || 1.4 (best) ||  || 6 ||  ||  || ~20 to 50 || ~20 to 50 || ~20 to 50 || ~20 to 50 || 22 ||  ||  ||  ||  ||  || 20 ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
|  Time Resolution (ns) ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
 +
|-
 +
|  Notes ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  || z || r phi || z  || r phi || z  || r phi
 +
|}

Revision as of 20:06, 5 November 2007

Related Papers

Silicon Vertex Detectors

Micromegas Detectors

Relevant Parameters

CN 2006-014 CN 2006-016

NIM 533

NIM 541

NIM 453 NIM 352 NIM 324 NIM 270 NIM 560 NIM 501 NIM 485 NIM 581 NIM in press
Thickness (_m) 300-320 300 400 325 400 280 300 300 300 200 300 320±15/320±15 290±15/295±15 300 300 300 300
Implant Strip Pitch (_m) 75 75 228 25 100/200 20 "25 29 33" 25 25 25 10 to 50 500 75 50 73 65 88 60 80 120 240 120 75 50 73 65 76 25.5
Readout Strip Pitch (_m) 150 150 50 50 150 50 146 65 152 51
Strip Width (_m) 9 60 12 50 10 55 12 10 15 25 35 up to 86 14 50 10 55 12 24 10
Implant Depth (_m) 1.2 5 5 1 2
# Readout Strips 256 256 512 629 56 1024 512 1024 512 512 1024 512 1024 512 1024 512
Strip Angle (degrees) ±1.5
Cut Size (mm x mm) 42.0 x 111.62 42.0 x 111.62 24 x 30 24 x 36 33 x 60 30 x 30 79.2 x 28.4 59 x 34 64.2 x 64.2
Active Area (mm x mm) 40.0 x 109.62
Depletion Voltage (V) 40<V<200 100 100 35 ~40 40<V<100
Readout Chip SVX4 Tektronix DSA602A FoxFET
Spatial Resolution (_m) ~40 _ ~20 4.5 to 7 1.4 (best) 6 ~20 to 50 ~20 to 50 ~20 to 50 ~20 to 50 22 20
Time Resolution (ns)
Notes z r phi z r phi z r phi